通风管道耐火极限的介绍!

来源:http://www.jnlxcfpy.com/添加时间:2019-06-25 14:19:16
  通风和排烟管是一种常见的设备在人们的生活中,当我们选择通风管,我们可以根据我们自己的情况,做出选择的设置,应注意通风和排烟感觉火极限设置要求,下面,我们跟随山东通风和排烟管制造商理解。
  Ventilation and smoke exhaust pipe is a common equipment in people's life. When we choose the ventilation pipe, we can choose the setting according to our own situation. We should pay attention to the limit setting requirements of ventilation and smoke exhaust feeling fire. Next, we follow the understanding of Shandong ventilation and smoke exhaust pipe manufacturers.
  山东地区通风排烟管道的选择:标注管道全长。管道具有矩形标识颜色。标签用于标记管道的颜色。管子用矩形标记,颜色标签用箭头标记。
  Selection of ventilation and smoke exhaust pipes in Shandong: Mark the full length of pipes. Pipes have rectangular marking colors. The label is used to mark the color of the pipe. The tube is marked with rectangle and the color tag is marked with arrow.
  排烟管在日常生活中很常见,它是厨房必不可少的,厨房烟火排烟管的防火性能也有很高的要求。但是你知道排气管的耐火极限吗?烟道设置和耐火极限应满足下列要求:
  Exhaust pipe is very common in daily life, it is essential for kitchen, kitchen fireworks exhaust pipe fire performance also has high requirements. But do you know the fire resistance limit of exhaust pipe? Flue setting and fire resistance limit should meet the following requirements:
  安装通风排烟管。排烟管及其连接部件应能在280℃下连续30分钟保证其结构完整性。
  Install ventilation exhaust pipe. The exhaust pipe and its connecting parts should be able to ensure its structural integrity for 30 minutes continuously at 280 C.
济南厨房排烟管道
  山东通风排烟管垂直设置的排烟管和排烟管应设置在独立的管井内,排烟管的耐火极限不得小于0.50h。
  The vertical exhaust pipe and exhaust pipe of Shandong ventilation and exhaust pipe should be set in an independent pipe well, and the fire resistance limit of the exhaust pipe should not be less than 0.50h.
  天花板上设置水平排烟管,其耐火极限不小于0.5 h,在遇到实际困难时可在室内直接设置,但管道的耐火极限不应小于1.00h。
  Horizontal smoke exhaust pipes are installed on the ceiling, and their fire resistance limit is not less than 0.5 H. They can be directly installed indoors in case of practical difficulties, but the fire resistance limit of pipes should not be less than 1.00 H.
  大耐火烟道位于天花板人行道内,通过防火区域的烟道应不小于1.00h,而大耐火烟道设备室和车库应不小于0.50h。
  The maximum fire-resistant flue should be located in the ceiling sidewalk, the flue through the fire-resistant area should be no less than 1.00h, and the maximum fire-resistant flue equipment room and garage should be no less than 0.50h.
  山东在通风和排烟管的选择上应注意管道的颜色标签,此外,排气管的耐火极限也有一定的要求,在垂直和水平设置防火的管道,这篇文章已经为您做了一个简单的描述,如果有其他问题,您可以咨询我们,我们也可以为您提供安装加工服务。
  In the selection of ventilation and smoke exhaust pipes in Shandong Province, attention should be paid to the color label of the pipes. In addition, the fire resistance limit of the exhaust pipes also has certain requirements. The article has already made a simple description for you. If there are other problems, you can consult us, and we can also provide installation and processing services for you.

上一篇:风机盘管系统的三种新风供给方式!